A solar inverter converts DC electricity from panels or batteries into usable AC power. String inverters are the usual choice for unshaded roofs, microinverters handle shade and panel-level monitoring, hybrid inverters add battery and backup capability, and off-grid inverters run without a utility connection. Match the inverter to the array, the battery, and the loads, not just the wattage label.
By WhichWatts editorial team · Updated October 25, 2026
What does a solar inverter do?
A solar inverter converts direct current from a PV array or battery into alternating current for household loads or the grid. It sets the AC voltage and frequency, tracks the array’s maximum power point in most designs, and provides safety functions such as anti-islanding in grid-tied systems. An inverter/charger also charges a battery and transfers between power sources.
Solar panels produce DC. Batteries store DC. Most homes, appliances, and tools run on AC. The inverter is the interface between those worlds. In a grid-tied system it also synchronizes its output with the utility waveform and stops exporting when the grid is unavailable, unless it is designed for islanded backup.
The inverter is not the same as a charge controller. A charge controller regulates charging from the array to a battery; an inverter converts battery or array DC to AC. A hybrid inverter may contain both functions, plus a transfer switch and battery charger, but those are separate jobs inside one enclosure.
The U.S. Department of Energy’s Solar Photovoltaic Cell Basics and the EIA’s Photovoltaics and electricity explain the DC output of PV and the inverter’s role in making it usable.
Inverter efficiency is not the only loss in a system. Shading, soiling, mismatch, wiring voltage drop, battery round-trip efficiency, and temperature all matter. A high-efficiency inverter cannot recover energy that the array never produced.
What are the main types of solar inverter?
The main types are string inverters, microinverters, hybrid inverters, and off-grid inverter/chargers. String inverters centralize conversion for one or more panel strings; microinverters convert at each panel; hybrid inverters add battery and backup functions to a grid-tied system; off-grid inverters run from a battery without utility interaction.
| Type | Where it sits | Best fit | Main trade-off |
|---|---|---|---|
| String inverter | One central unit, often near the service panel | Unshaded roof, one orientation, simple layout | One shaded panel can affect its string; high DC voltage on the roof |
| Microinverter | One unit per panel, under the module | Shade, multiple orientations, panel-level monitoring | More electronics on the roof; higher equipment cost |
| Hybrid inverter | Central unit with battery and backup connections | Grid-tied home that wants battery backup or self-consumption | Battery compatibility, backup wiring, and commissioning are more complex |
| Off-grid inverter/charger | Central unit connected to a battery bank | Cabin, remote site, or standalone system | No grid interaction; battery bank and generator planning are separate |
Some manufacturers also sell AC-coupled battery inverters that work alongside an existing string inverter. These are common when a homeowner adds storage to a system that already has a PV inverter. The battery inverter manages the battery and backup loads, while the existing PV inverter continues to produce.
The names are not perfectly standardized. A “hybrid” inverter may be battery-ready but not backup-ready, or it may support backup only with an optional accessory. Read the datasheet and single-line diagram rather than relying on the marketing category.
String inverter or microinverter?
Choose a string inverter for an unshaded roof with a single orientation and a straightforward layout, where lower equipment cost and centralized service matter. Choose microinverters when shade, multiple roof planes, panel-level monitoring, or easier module-level expansion matter more than upfront cost. The right answer depends on the roof and the lifecycle plan, not one efficiency number.
A string inverter connects panels in series. The current through the string is limited by the weakest panel, so shade, soiling, or a failed module can reduce output from the whole string. String designs can use multiple MPPTs to separate orientations, and DC optimizers can add panel-level tracking while keeping a central inverter.
Microinverters convert at each panel. Shade on one module has less effect on its neighbours, and each panel can report its own production. They also avoid high-voltage DC on the roof, which can simplify rapid-shutdown compliance in some designs. The trade-offs are more units to install and service, more heat and weather exposure on the roof, and usually a higher equipment cost per watt.
Questions that usually decide it:
- Shade: Is there regular shade from trees, chimneys, or nearby buildings?
- Roof planes: Do panels face more than one direction?
- Service access: Is the roof easy and safe to reach?
- Monitoring: Do you need panel-level data, or is system-level data enough?
- Expansion: Will you add panels in stages?
- Budget: What is the installed cost difference, not just the inverter price?
For a simple, unshaded roof, a string inverter is often the pragmatic choice. For a complicated roof, microinverters or DC optimizers may produce more over the year and make troubleshooting easier.
What is a hybrid inverter?
A hybrid inverter is a grid-tied inverter that can also manage a battery, charge it from solar or the grid, and supply backup loads. It usually combines an MPPT charge controller, battery interface, inverter, and transfer equipment. “Hybrid” does not guarantee whole-home backup or support for every battery; check the backup output, transfer time, and approved battery list.
A hybrid inverter can operate in several modes: solar to loads, solar to battery, battery to loads, grid to loads, and grid to battery. During an outage, it can disconnect from the grid and run selected loads from the battery and solar. The size of those loads depends on the inverter’s backup output and the battery’s usable energy.
There are two common architectures:
- DC-coupled: the battery connects to the same DC bus as the PV, often through a hybrid inverter. This can be efficient for new systems and keeps battery charging inside one ecosystem.
- AC-coupled: a battery inverter connects to the AC side, alongside an existing PV inverter. This is common for retrofits and can preserve an existing solar system.
Backup wiring is the part buyers underestimate. A whole-home backup requires a transfer switch or meter-level equipment and enough inverter and battery capacity for the whole house. A partial backup uses a separate essential-loads panel for selected circuits. The transfer time matters for computers and medical equipment; some inverters transfer in milliseconds, while others take longer.
If you add a generator, confirm the hybrid inverter supports generator input and can manage the charger and loads without backfeeding the generator. The installation must prevent utility and generator sources from being connected at the same time.
How efficient are solar inverters?
Many modern PV inverters convert about 95–98% of DC input to AC at rated conditions, but the number that matters is the weighted efficiency on the datasheet, not a peak figure. MPPT range, temperature derating, idle consumption, and battery round-trip losses can matter more in a real system than a one- or two-point efficiency difference.
Inverter datasheets usually report a peak efficiency and a weighted efficiency such as CEC efficiency in the United States or a European weighted figure elsewhere. Weighted efficiency reflects operation across a range of loads, which is closer to real behavior than a single best-case point.
Losses to consider beyond the inverter:
- Array losses: temperature, soiling, shading, mismatch, and wiring.
- DC/AC ratio: an inverter may clip peak production if the array is oversized relative to its AC rating. That can be an economic choice, not a fault.
- Battery round trip: charging and discharging a battery loses energy. The U.S. DOE storage basics page describes capacity and efficiency concepts; the manufacturer’s datasheet gives the actual round-trip figure.
- Standby consumption: an inverter draws some power at night or while idle. In a small off-grid system, that can be a meaningful share of daily energy.
- Temperature: a hot inverter may derate. Mounting and ventilation matter.
Do not choose an inverter solely because it is 0.5 percentage points more efficient. Reliability, service, monitoring, battery compatibility, and the quality of the installation usually have a larger effect on annual production.
How do I size a solar inverter?
For a grid-tied array, size the inverter around the array’s DC rating, location, tilt, and acceptable clipping, then confirm its DC input windows and AC output. For an off-grid system, size for continuous load and motor surge first, then check the battery voltage and charging current. In both cases, the datasheet limits and the installer’s design review decide the final model.
For grid-tied systems, designers often use a DC/AC ratio around 1.1–1.3 kW of array per kW of inverter AC rating. A higher ratio can reduce inverter cost per watt but may clip at midday; a lower ratio reduces clipping but costs more inverter capacity. The best ratio depends on local irradiance, tilt, temperature, and tariffs. NLR’s PVWatts can estimate hourly production and clipping for a specific location.
Check these datasheet limits:
- Maximum DC input voltage and the array’s cold-temperature open-circuit voltage.
- MPPT voltage range and the number of MPPTs.
- Maximum DC input current per MPPT and per string.
- AC output watts at the expected ambient temperature.
- Grid voltage and frequency settings, and the required listing for the utility.
- Rapid shutdown and arc-fault requirements in the local code.
For off-grid, start with the load table and motor surge. A 3 kW continuous inverter may be right for a small cabin but wrong for a well pump with a high locked-rotor current. Battery voltage also matters: a 12V inverter needs much larger cables than a 48V inverter for the same power.
The off-grid solar system guide walks through the load, battery, array, and inverter sizing in order.
What should I check for safety and reliability?
Confirm the inverter is listed for its intended use, has the required grid-interconnection certification, and is installed with the specified disconnects, overcurrent protection, and grounding. Check the warranty, service network, monitoring, and replacement plan. A grid-tied inverter must not energize a de-energized utility line.
In the United States, grid-interactive inverters are commonly evaluated to UL 1741 and installed under IEEE 1547 requirements, with local utility review. Rapid shutdown, arc-fault protection, and labeling are code requirements for many rooftop systems. An off-grid inverter may not carry a grid-interactive listing because it is not designed to parallel with the utility; that does not make it unsafe for a standalone battery system, but it does mean it cannot be used for grid interconnection.
Practical reliability checks:
- Warranty term and what it covers: parts, labour, shipping, and whether the manufacturer or installer handles the claim.
- Service access: is the unit in a reachable location, or on a hot roof?
- Monitoring: can you see production, faults, and battery state?
- Firmware and cybersecurity: does the unit require a cloud account, and how are updates delivered?
- Spare parts: how quickly can a replacement be sourced?
- Commissioning: are the grid settings, backup loads, and battery limits documented?
A solar system is a 20-year asset. The cheapest inverter is not necessarily the lowest-cost choice if service is slow or the model is discontinued.
How do I choose the right inverter?
Start with the system architecture: grid-tied without storage, grid-tied with backup, or off-grid. Then match the inverter to the array’s voltage and current, the battery’s approved list, the loads you need to back up, and the local code. Compare installed cost, warranty, monitoring, and service, not just the datasheet wattage.
A practical checklist:
- Define the job. Is this a new grid-tied array, a battery retrofit, a backup system, or a standalone off-grid site?
- Map the array. Module count, wattage, Voc at cold temperature, Vmp, current, orientation, and shade.
- Decide on storage. If you want a battery later, choose an inverter with a supported battery list and a clear expansion path.
- List the backup loads. Whole-home or essential circuits? What is the continuous and surge load?
- Check the grid rules. Utility approval, interconnection listing, rapid shutdown, and permits.
- Compare lifecycle cost. Equipment, installation, warranty, monitoring subscription, service, and replacement.
- Get a single-line diagram. It should show the array, inverter, battery, disconnects, main panel, and backup panel.
If you are comparing complete systems rather than components, the solar battery storage guide and the off-grid solar system guide cover the storage and load side. For portable systems, the power station catalog is a different category with integrated inverters and much smaller batteries.
Where to start shopping
The three lowest cost-per-watt-hour stations in the live US catalog. Affiliate links; the ranking is not paid.


Retailer links are affiliate links. WhichWatts may earn a commission; the shortlist is ranked by cost per watt-hour, not by commission.
Shop by brand
Direct links to manufacturer stores. These are affiliate links and we may earn a commission.
Compare before you buy
Browse every model · Cost per watt-hour chart · Best for home backup · Size a system for your appliances
Common questions
What is the difference between a string inverter and a microinverter?
A string inverter centralizes conversion for a group of series-connected panels. A microinverter converts at each panel. Microinverters handle shade and mixed orientations better and provide panel-level monitoring, but they usually cost more and put more electronics on the roof. String inverters are often simpler and cheaper for an unshaded, single-orientation array.
Do I need a hybrid inverter for battery backup?
Not necessarily. A hybrid inverter is convenient because it combines solar conversion, battery management, and backup transfer in one unit. An AC-coupled battery inverter can add backup to an existing solar system. The right choice depends on whether you are building a new system, retrofitting storage, and how much of the home you need to back up.
Can I add a battery to a solar system later?
Often, but it is easier if the original inverter or battery system was designed for expansion. Check the approved battery list, the inverter’s backup output, the age and communication protocol of the existing equipment, and whether the main panel has space for a backup panel. A retrofit may use an AC-coupled battery inverter rather than replacing the PV inverter.
How efficient is a solar inverter?
Many modern PV inverters convert about 95–98% of DC input to AC at rated conditions. The weighted efficiency on the datasheet is more useful than the peak figure. In a full system, array temperature, shading, soiling, DC/AC ratio, battery round-trip losses, and standby consumption can matter more than a small efficiency difference.
Can I use an off-grid inverter with a utility connection?
No, not as a grid-interactive inverter. An off-grid inverter is designed to run from a battery and may not be listed to parallel with the utility. Connecting one to a building with utility service requires approved transfer equipment so it cannot backfeed the grid. Use a qualified electrician and the utility’s interconnection process.
What size inverter do I need for my solar panels?
For a grid-tied array, the inverter’s AC rating is often around 0.75–0.9 of the array’s DC wattage, but the right DC/AC ratio depends on location, tilt, temperature, and acceptable clipping. For off-grid, size the inverter for continuous load and motor surge, then confirm the battery voltage and charge-controller limits. The datasheet and a site-specific design are the final check.
Sources
- U.S. Department of Energy — Solar Photovoltaic Cell Basics — How PV cells produce DC and how modules are connected into arrays.
- U.S. Energy Information Administration — Photovoltaics and electricity — The inverter’s role in converting DC to AC for loads and the grid.
- U.S. Department of Energy — Solar Integration: Solar Energy and Storage Basics — Storage capacity, power, and efficiency concepts for hybrid systems.
- National Laboratory of the Rockies — PVWatts — Location-specific production estimates, including tilt, azimuth, and losses.
- IEEE 1547 — Standard for Interconnection and Interoperability of Distributed Energy Resources — Grid-interconnection requirements referenced by U.S. utilities and UL 1741.
Related: Off-grid solar system guide · Solar panel types · Solar battery storage · Battery backup guide · Solar panel sizing calculator